Journal of Scientific Dentistry

Register      Login

VOLUME 2 , ISSUE 2 ( July-December, 2012 ) > List of Articles

CASE REPORT

Prosthetic Management of a Patient with Ocular Defect with Custom Ocular Prosthesis

Arunjai Kumar R, Krishnaraj R, Vijitha D

Keywords : evisceration, enucleation, exenteration, anaophthalmos, orbital prosthesis

Citation Information : R AK, R K, D V. Prosthetic Management of a Patient with Ocular Defect with Custom Ocular Prosthesis. 2012; 2 (2):56-60.

DOI: 10.5005/jsd-2-2-56

License: CC BY-NC 4.0

Published Online: 30-07-2020

Copyright Statement:  Copyright © 2012; The Author(s).


Abstract

As loss of an eye has high psycho-social impact on a patient, the main aim in management in such patients is to replace the missing tissues with an artificial prosthesis, not only to restore optimum aesthetics, facial symmetry and function, but also the self-confidence of the patient. These prosthesis are challenging as they try to reconstruct a mobile organ with a nonmobile prosthesis. Treatment includes implants and acrylic eye prosthesis. Although implant eye prosthesis has superior outcome, due to economic factors it may not be advisable for all patients. Therefore a custom-made ocular prosthesis is a viable alternative. This case report explains a custom-made ocular acrylic prosthesis made for an anophthalmic patient.


PDF Share
  1. Doshi PJ, Aruna B. Prosthetic management of patient with ocular defect. J Ind Prosthodont Soc 2005;5:37-8.
  2. Raflo GT. Enucleation and evisceration. In: Tasmun W, Jaeger E eds. Duane's Clinical Ophthalmology, Revised edn, Vol. 5. Philadelphia: Lippincott-Raven, 1995;1-25.
  3. Lubkin V, Sloan S. Enucleation and psychic trauma. Adv Ophthalmic Plast Reconstr Surg 1990;8:259-62.
  4. Guttal SS, Patil NP, Nadiger RK, Basutkar B. Use of acrylic resin base as an aid in retaining silicone orbital prosthesis. J Indian Prosthodontic Soc 2008;8:112-15.
  5. Patil SB, Meshramkar R, Naveen BH, Patil NP. Ocular prosthesis: a brief review and fabrication of an ocular prosthesis for a geriatric patient. Gerodontology 2008;25:57-62.
  6. Artopoulou II, Montogomery PC, Wesley PJ, Lemon JC. Digital imaging in the fabrication of ocular prostheses. J Prosthet Dent 2006;95: 327-30.
  7. Ow RKK, Amrith S. Ocular prosthetics: use of a tissue conditioner material to modify a stock ocular prosthesis. J Prosthet Dent 1997;78:218-22.
  8. Bartlett SO, Moore DJ. Ocular prosthesis: a physiologic system. J Prosthet Dent 1973; 29: 450-59
  9. Guerra LR, Finger IM, Echeverri J, Shipman B. Impression making, sculpting, and coloring of orbital prostheses. Adv Ophthalmic Plast Reconstr Surg. 1992;9:287-96.
  10. Taicher S, Steinberg HM, Tubiana I, Sela M. Modified stock-eye ocular prosthesis. J Prosthet Dent 1985;54:95-8.
  11. Benson P. The fitting and fabrication of a custom resin artificial eye. J Prosthet Dent 1977;38:532-38.
  12. Mathews MF, Smith RM, Sutton AJ, Hudson R. The ocular impression: a review of the literature and presentation of an alternate technique. J Prosthodont 2000;9:210-16.
  13. Cain JR. Custom ocular prosthetics. J Prosthet Dent 1982;48:690-94.
  14. Dyer NA. The artificial eye. Aust J Ophthalmol 1980;8:325-27.
PDF Share